MARKAZDAN QOCHMA VENTILYATOR ISH G‘ILDIRAGINING PARRAKLARARO OQIM KESIMIGA KONSTRUKTIV PARAMETRLARNING TA’SIRINI GEOMETRIK BAHOLASH

Mualliflar

  • Rahmonov Soxibjon Shokirjon o‘g‘li Qo‘qon davlat universiteti, Muhandislik texnologiyalari kafedrasi assistenti ##default.groups.name.author##

Annotatsiya

Oddiy superfosfat ishlab chiqarish sexidagi 12 parrakli markazdan qochma ventilyator ish g‘ildiragi chiqishidagi erkin geometrik kesim konstruktiv parametrlarga bog‘liq holda nazariy baholandi. Nominal tashqi diametr D₂ = 1238 mm va parraklar soni Z = 12 bo‘yicha aylana qadami aniqlandi. Parrakning tangensial proyeksiyadagi shartli to‘sish kengligi asosida o‘lchamsiz model tuzildi. Besh variantda to‘silish ulushi 1,23–3,70 %, koeffitsient sezgirligi esa har 1 mm kenglik uchun taxminan 0,309 foiz punkt bo‘ldi. Qo‘shimcha hisoblarda parraklar sonining nazariy ta’siri qiyoslandi. Natijalar real gaz sarfi, bosim yoki samaradorlikni o‘lchash natijasi emas.

##plugins.themes.default.displayStats.downloads##

##plugins.themes.default.displayStats.noStats##

Adabiyotlar

[1] Sarimsakov O.Sh., Ismoilov H.K., Haydarov H.B., To‘xtaboyeva S.T. Parrakli diskning ventilyator qobig‘ida joylashishi holatining ish unumdorligiga ta’siri. To‘qimachilik va moda sanoatida ilm-fan va innovatsiyalar. 2023;1(1):35–37. https://journalhub.uz/uploads/jurnallar/2024/2024-1.pdf

[2] Xurmamatov A.M., Xametov Z.M., Mo‘minov J.A. Havo yordamida sovitish qurilmasi konstruktiv parametrlarining sovitish samaradorligiga ta’siri. FarPI ilmiy-texnika jurnali. 2023;27(2):162–165. ISSN 2181-7200.

[3] Zhao X., Guan J., Wang T., Liu X., Xu Q., Zhou J. Optimization of Impeller Structure Parameters of a Centrifugal Fan in a Powered Air-Purifying Respirator Power System. Processes. 2024;12(2):353. DOI: 10.3390/pr12020353.

[4] Dvořák V., Elbarghthi A.F.A. Influence of Number and Thickness of Blades on the Performance of Centrifugal Fans. Proceedings of the 31st DAAAM International Symposium. 2020:724–727. DOI: 10.2507/31st.daaam.proceedings.100.

[5] CFturbo GmbH. Impeller — Blade setup: blade thickness and blockage mode. Technical documentation. https://manual.cfturbo.com/en/bl_setup.html

[6] ISO 5801:2017. Fans — Performance testing using standardized airways; ISO 5801:2017/Amd 1:2025. https://www.iso.org/standard/56517.html; https://www.iso.org/standard/88365.html